[ Pobierz całość w formacie PDF ]
.ÿþLOADING ADMINISTRATION, SIGNAL ATTRIBUTES, LOAD Strona 1 z 4COMMAND DESCRIPTION1/190 82-CNZ 211 1175 Uen ELASALLOADING ADMINISTRATION, SIGNALATTRIBUTES, LOAD1 Format1.1 CommandLASAL:SIGNAL=signal[,FORMAT=format][,INTWK=intwk][,MULT=mult][,TYPE=type][,JB=jb][,BUF=buf];1.2 ParametersBUF=buf Buffered signal marker.Identifier.YES Signal is always bufferedwhen sent.NO Signal may be buffered orsent directly.FORMAT=format Signal format.Numeral 0-15.0 PR0.1 PR0,DR0.2 PR0,DR0 - DR1.3 PR0,DR0 - DR2.4 PR0,DR0 - DR3.5 PR0,DR0 - DR4.6 PR0,DR0 - DR5.7 PR0,DR0 - DR6.8 PR0,DR0 - DR7.9 PR0,DR0 - DR11.10 PR0,DR0 - DR15.11 PR0,DR0 - DR19.12 PR0,DR0 - DR23.13 Reserved (PR0,DR0 - DR1 ).14 Reserved (PR0,DR0 - DR7 ).15 Reserved (PR0,DR0 - DR23).INTWK=intwk Signal interwork.Identifier.CPCP CP-CP signal.RPCP RP-CP signal.EMCP EMRP-CP signal.CPRP CP-RP signal.CPEM CP-EMRP signal.JB=jb Job buffer.Identifier.JBA Job buffer A.file://C:\CODy\LASAL.html 2005-03-02LOADING ADMINISTRATION, SIGNAL ATTRIBUTES, LOAD Strona 2 z 4JBB Job buffer B.JBC Job buffer C.JBD Job buffer D.NO No buffer, signal is sentdirectly on current level.MULT=mult Multiple flag.Identifier.NO Unique signal.YES Multiple signal.SIGNAL=signal Name for signal to be created.Identifier, 1.15 characters.TYPE=type Signal type.Identifier.SI Single signal.CF Combined forward signal.CB Combined backward signal.2 FunctionThe command defines a signal, and its associatedattributes.This enables signal corrections to beentered at an exchange site.A signal with contradictory attributes may not bedefined with the command.Missing parameters in thecommand are given default values, these are listedbelow.PARAMETER DEFAULT VALUEFORMAT Signal format : 0INTWK Signal interwork : CPCPMULT Multiple marker : NOTYPE Signal type : SIJB Job buffer : JBDBUF Buffered signal marker : YESThe allowable combinations of attributes for the commandare shown in the table below.+------+------------------------+----+--------+----------+---+!FORMAT! INTWK !MULT! TYPE ! JB !BUF!! !CPCP RPCP EMCP CPRP CPEM!Y N!SI CF CB!A B C D NO!Y N!+------+------------------------+----+--------+----------+---+! * ! * !* *! * !- - - - - !- -!! * ! * !* *! * !- - - - - !- -!! * ! * ! *! * !- - - - - !- -!! * ! * * !* *! * !- - - - - !- -!! * ! * * !* *! * !- - - - - !- -!+------+------------------------+----+--------+----------+---+Note: * allowable combination- not relevantThe order remains after system restart.3 Examplesfile://C:\CODy\LASAL.html 2005-03-02LOADING ADMINISTRATION, SIGNAL ATTRIBUTES, LOAD Strona 3 z 43.1 Example 1LASAL:SIGNAL=NEWSIG,INTWK=CPCP;The signal NEWSIG, is defined with attributes : FORMAT=0,INTWK=CPCP, MULT=NO, TYPE=SI, JB=JBD, and BUF=YES.4 Printout4.1 Check PrintoutYes.4.2 Procedure PrintoutsEXECUTEDNOT ACCEPTEDfault typeFault type:FUNCTION BUSYFunction busy.FORMAT ERRORFormat error.UNREASONABLE VALUEdetails Unreasonable value.FAULT CODE 160CPS ACTIVITY IN PROGRESSCPS activity in progress.The write key has not been received.Wait and try again.FAULT CODE 506INVALID COMBINATION OF SIGNAL ATTRIBUTESThe combination of signal attributesis not permitted.FAULT CODE 508INSUFFICIENT SPACE IN SIGNAL SYMBOL TABLEIt is not possible to store additionalsignal symbols.FAULT CODE 512SIGNAL NAME ALREADY USEDThe signal name is already defined.4.3 Answer Printoutsfile://C:\CODy\LASAL.html 2005-03-02LOADING ADMINISTRATION, SIGNAL ATTRIBUTES, LOAD Strona 4 z 4-4.4 Result Printouts-5 LoggingYes.6 Command Category GroupRecommended value 10 (H'A).7 Command Receiving BlockLASYMBfile://C:\CODy\LASAL.html 2005-03-02 [ Pobierz caÅ‚ość w formacie PDF ]